Shanghai Chucheng Information Technology Co.,Ltd.
Products
Contact Us
  • Contact Person : Mr. Daisy Wang
  • Company Name : Shanghai Chucheng Information Technology Co.,Ltd.
  • Tel : 86-8621-58718070
  • Fax : 86-8621-58714662
  • Address : Shanghai,Shanghai,Room 110,No.389 JinWan Road,Shanghai ,China
  • Country/Region : China
  • Zip : 201206

Huawei DWDM Transport System OptiX OSN 8800

Huawei DWDM Transport System OptiX OSN 8800
Product Detailed
Related Categories:Agricultural Product Stock
Quick DetailsPlace of Origin:Guangdong, China (Mainland)Brand Name:HuaweiModel Number:OSN8800Power Supply:-48V DC to -60V DCOperating temperature:0℃~45℃Operating humidity:10% RH~90% RHRate per Channel:100/200/400GERate per Channel (maximum):100 GE, 200 GE, 400 GEEquipment type:DWDM Transport systemPackaging & DeliveryPackaging Details:Original Huawei packing or according to the customer's requirementsDelivery Detail:Within 5 working days after receipt of paymentHuawei DWDM Transport system OptiX OSN8800Product DescriptionMid-range 10/40/100 GE platform for integrated OTN/WDM/SDH networking. Carrier-grade reliability with up to 8 Tbit/s capacity ideal for core networks and Metropolitan Area Networks in broadcast television, Smart Grid electric power, and transportation industries. Advanced networking and management features include OTN grooming, long-haul WDM, Tbit/s cross-connection, OTN, and SDH support, and end-to-end monitoring and dynamic fault detection. Visual management interfaces simplify O&M and reduce TCO.The OptiX OSN 8800 supports 40 Gbit/s and 100 Gbit/s line rates and a 6.4 Tbit/s cross-connect capacity. It features power saving, and high reliability and maintainability.Detailed ImagesProduct FeaturesHighest Cross-Connect Capacity with Flexible Large-Capacity Service Grooming ● Features high cross-connect capacity. A single subrack supports a maximum of 6.4 Tbit/s cross-connect capacity, implementing large-capacity service grooming. Only one subrack is required for the large-capacity service grooming and therefore lowers power consumption and reduces the floor space. ● Supports multi-granularity OTN cross-connection, that is, ODUk cross-connection, where k can be 0, 1, 2, 2e, 3, 4, or flex. ● Supports unified switching capabilities of VC, ODUk, and packet services by using universal line boards, which converges service grooming planes, and supports flexible bandwidth allocation.Huge Bandwidth Provisioning with Flexible High-Density Architecture● Supports hybrid transmission of 10 Gbit/s, 40 Gbit/s, and 100 Gbit/s signals, and supports a smooth upgrade from a low-rate network to a high-rate network. ● Supports ePDM-QPSK modulation for 100 Gbit/s signals, requiring no dispersion compensation modules (DCMs) and simplifying network configurations. The advanced return to zero (RZ), forward error correction (FEC), and digital signal processing (DSP) algorithms implement ultra long-haul transmission of 100 Gbit/s signals, which increases the optical signal-to-noise ratio (OSNR) tolerance and transmission distance. ● Satisfies requirements on large-bandwidth transmission using 40 Gbit/s and 100 Gbit/s line rates. Provides the highest integration in the industry and supports 100 Gbit/s capacity.Tier 1 Reliability and Mass Data Transmission with Optimal Architecture● Provides multiple network-level protection schemes and intelligent network management based on automatically switched optical network (ASON)/generalized multiprotocol label switching (GMPLS) technologies to protect all fibers and services. ● Provides protection for power supply devices, fans, communication control boards, and the cross-connection resource pool.Advanced Power Saving Technology with Low Power Consumption and High Maintainability, Providing the Minimizing OPEX● Newly supports 19-inch subracks and can be installed in various types of cabinets, such as 19-inch cabinet or ETSI cabinet. ● Implements advanced visual management on OSNR monitoring. ● Supports seamless interconnection with OptiX OSN 6800/3800/1800 and achieves end-to-end network management.SpecificationsSpecificationsOptiX OSN 8800 T16OptiX OSN 8800 T32OptiX OSN 8800 T64Product appearance Dimensions (mm)498 (W) x 295 (D) x 450 (H)498 (W) x 295 (D) x 900 (H)498 (W) x 580 (D) x 900 (H)Number of slots for service boards163264SwitchOptical1 to 9-degree ROADMElectrical● 1.6T ODUk(k=0, 1, 2, 2e, 3, 4, flex)● 640G VC-4 and 20G VC-3/VC-12● 800G PacketEnhanced subrack:● 3.2T ODUk(k=0, 1, 2, 2e, 3, 3e, 4, flex)● 1.28T VC-4 and 80G VC-3/VC-12● 1.6T PacketGeneral subrack:● 2.56T ODUk(k=0, 1, 2, 2e, 3, 4, flex)● 1.28T VC-4 and 80G VC-3/VC-12● 640G PacketEnhanced subrack:● 6.4T ODUk(k=0, 1, 2, 2e, 3, 4, flex)● 1.28T VC-4 and 80G VC-3/VC-12General subrack:● 2.56T ODUk(k=0, 1, 2, 2e, 3, flex)● 1.28T VC-4 and 80G VC-3/VC-12Wavelength (max)DWDM: 80-ch, CWDM: 8-chWavelength rangeDWDM: 1529.16 nm to 1560.61 nm (Band-C, ITU-T G.694.1)CWDM: 1471 nm to 1611 nm (Band S+C+L, ITU-T G.694.2)Max. rate per channel100Gbit/s (OTU4)Max. distanceMulti-span transmission (without electrical regeneration): 32 span x 22 dB/span (10G), 25 span x 22 dB/span (40G), 20 span x 22 dB/span (100G)Ultra-long single-span transmission: 1 span x 81 dB/span (10G), 1 span x 71 dB/span (40G)Service types supportedSDH, SONET, Ethernet, SAN, OTN, VideoLine rate2.5 Gbit/s, 10 Gbit/s, 40 Gbit/s, 100 Gbit/sMax. capacity per PID group200 Gbit/sTopologyPoint-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring and meshRedundancy and ProtectionNetwork level protection (OTN)Optical line protection, intra-board 1+1 protection, client 1+1 protection, ODUk SNCP, tributary SNCP, SW SNCP, ODUk SPRing protection, OWSPNetwork level protection (OCS)Linear MSP, MSP ring, transoceanic MSP ring, SNCP, SNCTPNetwork level protection (Ethernetand packet)DBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP,PW APS, STP and RSTP, Tunnel APS, VLAN SNCPDBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP,PW APS, STP and RSTP, Tunnel APS, VLAN SNCPDBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP, STP and RSTP, VLAN SNCPEquipment level protectionPower redundancy, fan redundancy, cross-connect board redundancy, system control and communication board redundancy, centralized clock board redundancy, AUX Board 1+1 RedundancyOptical power managementALS, AGC, ALC, APE, IPA, OPASynchronization● Synchronous Ethernet clock● IEEE 1588v2● 2 Mbit/s or 2 MHz (with the SSM function), ITU-T G.703-compliant external clock source● External time source (1PPS+TOD)Operation EnvironmentSubrack temperature:● Long-term operation: 5°C (41 °F) to 40°C (104 °F)● Short-term operation: -5°C (23 °F) to 45°C (113 °F)Relative humidity:● Long-term operation: 5% to 85%● Short-term operation: 5% to 90%ASON● An OTN network supports the Optical-Layer ASON and electrical-Layer ASON.● An OCS network supports the SDH ASON feature.Service Board/ PortTable 1 Implementation of service mapping on each boardBoard TypeImplementationNon-data boardsOTU boardsThe OTU board receives client services. After encapsulation, mapping, and OTN framing processes, client services are converted into OTU optical signals and are sent to the WDM side.Tributary boards and line boardsThe tributary board receives client services, which are encapsulated and mapped into ODUk signals. ODUk signals are transmitted to the line board through the centralized cross-connect board. The line board multiplexes and maps the ODUk signals into OTU optical signals and sends the signals to the WDM side.Data boardsPacket boards (EG16, EX2, and PND2)The EG16 or EX2 board receives Ethernet services on the client side. After L2 service processing on client side, the services are transmitted to the PND2 board through the centralized cross-connect board. The PND2 board maps the services into OTU2 optical signals after L2 service processing on network side and sends the signals to the WDM side.EoO boards (TEM28)The TEM28 board receives Ethernet services on the client side. After L2 service processing, the services are encapsulated and mapped into ODUk signals, which are then transmitted to the line board through the centralized cross-connect board. The line board multiplexes and maps the ODUk signals into OTUk optical signals and sends the signals to the WDM side.EoW boards (LEM24 and LEX4)The LEM24 or LEX4 board receives Ethernet services on the client side. After L2 service processing, client Ethernet services are mapped into OTU2 optical signals and are sent to the WDM side.EoS boards (EGSH and EAS2)The EGSH or EAS2 board receives Ethernet services on the client side. After L2 service processing, client Ethernet services are encapsulated and mapped into VC signals, which are transmitted to the OCS line board through the centralized cross-connect board. The OCS board multiplexes and maps the VC signals into STM-N optical signals, and sends the signals to the line side.Packaging & ShippingTrade terms: FOB,CIF,CFR,etc.Price terms:L/C,D/P,T/T,Western Union,Paypal.Payment terms:T/T in advancePort: ShanghaiLead time: waithin 5 working days after receipt of paymentShipment:Express,Air,SeaSample availability: Yes(not free)   Our Services1)  We can provide detail documents and remote help for device installation and configuration.2)  Warranty: 1 year. ( After the quality guarantee period began to charge appropriate maintenance service fee.)3) Our company promises goods enjoy full return due to quality problem since goods delivered within 7 days or 15 days , returned goods must keep original state and it's accessories are complete. 


Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.